Technical Specifications

Specification Details
Model TC2000-G2
Cat.No. 5034112400
Sample Capacity 0.2 mL 96-Well PCR Plate | 0.2 mL 8-Tube PCR Strip | 0.2 mL PCR Tube
Module 48 × 0.2 mL
Heating Temperature Range 0-105℃
Lid Temperature Range 30-115℃
Temperature Display Accuracy 0.1℃
Temperature Control Accuracy ±0.1℃
Temperature uniformity @55℃ ±0.2℃
Max. Heating/Cooling Rate 5℃/Sec
Gradient Temperature Setting Range 30-105℃
Gradient Range 1-25℃,Turn off gradient on input 0
Adapter block material Aluminum
Display 10.1inches LCD 1280×800
Input Touch panel
User defined file system 1-25℃, enter 0 to turn off the gradient
Power off protection Yes
Voltage,Frequency 100-240V,50/60HZ,1000W
Dimension[WxDxH] 310×422×264mm
Weight 11Kg

Description

The TC2000-G1/G2/G3 Thermal Cycler Gradient (TC2000-G2) is a thermal cycler supplied for laboratory and research use in Riyadh, Dammam, Dhahran, Jubail, Al Khobar, Jeddah, Makkah, Yanbu and Jazan across Saudi Arabia.

  • 10.1-inch large screen new Ul interface, divided into single-channel / dual-channel /three-channel, to meet differentexperimental requirements
  • With advanced gradient temperature control technology, high-perfomance and long-lasting Peltier refrigeration andheating,which can achieve precise temperature control in zones.
  • Multi-channel module design, can run several diferent PCR gradient programs at the sametime, to achievemulti-purpose machine
  • Self-adaptive pressure lever hot cap, close and tighten the cap in one step, can be adapted to different heights of testtubes
  • Supports up to 199 cycles to perform the next operation, and runs a countdown disc to visually display the remainingtime
  • Edge temperature compensation technology for good temperature uniformity and gradient settings for easy optimisationof expenmental conditions
  • Real-time display of the running status ofthe programme, you can set the security account and password according to customer demand
  • Automatic power failure protection, automatically execute unfinished cycles after power restoration to ensure the safeoperation ofthewhole amplification process.
  • Hot lid temperature and hot lid operating mode can be set to meet different experimental application requirements
  • USB interface, support for U-disk storage/reading PCR data, support for U-disk software update, can be customised tomeet the function of multiple file storage, support for Touch down PCR and Long PCR experiments